Lei Dong
University of Pennsylvania · Rehabilitation Medicine
Active 1985–2024
Research topics
- Computer Science
- Medicine
- Internal medicine
- Optics
- Physics
- Nuclear engineering
- Surgery
- Medical physics
- Cancer research
- Radiology
- Pathology
- Nuclear physics
- Biology
- Engineering
- Nuclear medicine
Selected publications
International Journal of Particle Therapy · 2021 · 1 citations
- Computer Science
- Nuclear medicine
- Computer Science
INTRODUCTION: The intracranial skull-base meningioma is in proximity to multiple critical organs and heterogeneous tissues. Steep dose gradients often result from avoiding critical organs in proton treatment plans. Dose uncertainties arising from setup errors under image-guided radiation therapy are worthy of evaluation. PATIENTS AND METHODS: Fourteen patients with skull-base meningioma were retrospectively identified and planned with proton pencil beam scanning (PBS) single-field uniform dose (SFUD) and multifield optimization (MFO) techniques. The setup uncertainties were assigned a probability model on the basis of prior published data. The impact on the dose distribution from nominal 1-mm and large, less probable setup errors, as well as the cumulative effect, was analyzed. The robustness of SFUD and MFO planning techniques in these scenarios was discussed. RESULTS: The target coverage was reduced and the plan dose hot spot increased by all setup uncertainty scenarios regardless of the planning techniques. For 1 mm nominal shifts, the deviations in clinical target volume (CTV) coverage D99% was -11 ± 52 cGy and -45 ± 147 cGy for SFUD and MFO plans. The setup uncertainties affected the organ at risk (OAR) dose both positively and negatively. The statistical average of the setup uncertainties had <100 cGy impact on the plan qualities for all patients. The cumulative deviations in CTV D95% were 1 ± 34 cGy and -7 ± 18 cGy for SFUD and MFO plans. CONCLUSION: It is important to understand the impact of setup uncertainties on skull-base meningioma, as the tumor target has complex shape and is in proximity to multiple critical organs. Our work evaluated the setup uncertainty based on its probability distribution and evaluated the dosimetric consequences. In general, the SFUD plans demonstrated more robustness than the MFO plans in target coverages and brainstem dose. The probability-weighted overall effect on the dose distribution is small compared to the dosimetric shift during single fraction.
Cancer Research · 2021 · 179 citations
- Medicine
- Pathology
- Cancer research
In studies of electron and proton radiotherapy, ultrahigh dose rates of FLASH radiotherapy appear to produce fewer toxicities than standard dose rates while maintaining local tumor control. FLASH-proton radiotherapy (F-PRT) brings the spatial advantages of PRT to FLASH dose rates (>40 Gy/second), making it important to understand if and how F-PRT spares normal tissues while providing antitumor efficacy that is equivalent to standard-proton radiotherapy (S-PRT). Here we studied PRT damage to skin and mesenchymal tissues of muscle and bone and found that F-PRT of the C57BL/6 murine hind leg produced fewer severe toxicities leading to death or requiring euthanasia than S-PRT of the same dose. RNA-seq analyses of murine skin and bone revealed pathways upregulated by S-PRT yet unaltered by F-PRT, such as apoptosis signaling and keratinocyte differentiation in skin, as well as osteoclast differentiation and chondrocyte development in bone. Corroborating these findings, F-PRT reduced skin injury, stem cell depletion, and inflammation, mitigated late effects including lymphedema, and decreased histopathologically detected myofiber atrophy, bone resorption, hair follicle atrophy, and epidermal hyperplasia. F-PRT was equipotent to S-PRT in control of two murine sarcoma models, including at an orthotopic intramuscular site, thereby establishing its relevance to mesenchymal cancers. Finally, S-PRT produced greater increases in TGFβ1 in murine skin and the skin of canines enrolled in a phase I study of F-PRT versus S-PRT. Collectively, these data provide novel insights into F-PRT-mediated tissue sparing and support its ongoing investigation in applications that would benefit from this sparing of skin and mesenchymal tissues. SIGNIFICANCE: These findings will spur investigation of FLASH radiotherapy in sarcoma and additional cancers where mesenchymal tissues are at risk, including head and neck cancer, breast cancer, and pelvic malignancies.
Design, Implementation, and in Vivo Validation of a Novel Proton FLASH Radiation Therapy System
International Journal of Radiation Oncology*Biology*Physics · 2020 · 462 citations
- Computer Science
- Medical physics
- Computer Science
PURPOSE: Recent studies suggest that ultrahigh-dose-rate, "FLASH," electron radiation therapy (RT) decreases normal tissue damage while maintaining tumor response compared with conventional dose rate RT. Here, we describe a novel RT apparatus that delivers FLASH proton RT (PRT) using double scattered protons with computed tomography guidance and provide the first report of proton FLASH RT-mediated normal tissue radioprotection. METHODS AND MATERIALS: Absolute dose was measured at multiple depths in solid water and validated against an absolute integral charge measurement using a Faraday cup. Real-time dose rate was obtained using a NaI detector to measure prompt gamma rays. The effect of FLASH versus standard dose rate PRT on tumors and normal tissues was measured using pancreatic flank tumors (MH641905) derived from the KPC autochthonous PanCa model in syngeneic C57BL/6J mice with analysis of fibrosis and stem cell repopulation in small intestine after abdominal irradiation. RESULTS: The double scattering and collimation apparatus was dosimetrically validated with dose rates of 78 ± 9 Gy per second and 0.9 ± 0.08 Gy per second for the FLASH and standard PRT. Whole abdominal FLASH PRT at 15 Gy significantly reduced the loss of proliferating cells in intestinal crypts compared with standard PRT. Studies with local intestinal irradiation at 18 Gy revealed a reduction to near baseline levels of intestinal fibrosis for FLASH-PRT compared with standard PRT. Despite this difference, FLASH-PRT did not demonstrate tumor radioprotection in MH641905 pancreatic cancer flank tumors after 12 or 18 Gy irradiation. CONCLUSIONS: We have designed and dosimetrically validated a FLASH-PRT system with accurate control of beam flux on a millisecond time scale and online monitoring of the integral and dose delivery time structure. Using this system, we found that FLASH-PRT decreases acute cell loss and late fibrosis after whole-abdomen and focal intestinal RT, whereas tumor growth inhibition is preserved between the 2 modalities.
Recent grants
NIH · $95.0M · 2014
Frequent coauthors
- 197 shared
Laurence E. Court
The University of Texas MD Anderson Cancer Center
- 153 shared
Radhe Mohan
- 116 shared
Peter Balter
- 88 shared
Jinzhong Yang
- 82 shared
Adam S. Garden
The University of Texas MD Anderson Cancer Center
- 75 shared
James M. Metz
- 64 shared
L Zhang
Zhangzhou Normal University
- 64 shared
Rajat J. Kudchadker
Education
- 1995
Ph.D. Medical Physics, MD Anderson Cancer Center - Dept. of Radiation Physics
University of Texas Health Science Center at Houston
Similar researchers at University of Pennsylvania
- Resume-aware match score
- Save to shortlist
- AI-drafted outreach
See your match with Lei Dong
PhdFit ranks faculty by your research interests, methods, and publications — grounded in their actual work, not templates.
- Free to start
- No credit card
- 30-second signup